Phoenix NCC-51 Hematology Analyzer

Neomedica’s well-established 5-diff cell counter – an open system with the addition of reticulocyte analysis forms an important constituent of any middle-sized laboratory.

Description

Neomedica’s well-established 5-diff cell counter – an open system with the addition of reticulocyte analysis forms an important constituent of any middle-sized laboratory. Phoenix NCC-51 is an important part of Neomedica’s 5-diff portfolio and has already proven itself as a gold standard for comprehensive results in labs and hospitals of moderate workload and throughput. Alongside only 4 onboard reagents (1 sheath), this analyzer uses a separate reagent for reticulocyte analysis as an additional benefit to medical practitioners.

With 4 different determination methods and through calculations of different angles via laser scatters, this instrument delivers the complete picture, including cell size, granularity and complexity. Characterized by simplicity in operation, a comprehensive QC program and high-quality reagents, this robust device serves to improve the quality of healthcare and to reduce the costs by minimizing the consumption and providing fast, reliable and accurate results at the same time.

Technical specification

Principle WBC/DIFF: Flow cytometry, semiconductor, laser light multi-dimensional cell classification
WBC Analysis: Optical and impedance measurementsRBC/PLT Analysis: Impedance MethodHGB Test: Cyanide-free reagent colorimetry
Working mode Double WBC counting mode (impedance & optical)
5-part differentiation of WBC

28 parameters + 2 histograms for RBC and PLT, 2 5-part differential scatter-grams for eosinophils and neutrophils and 2 3-D stereograms

Parameters WBC, LYM#, MON#, NEU#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS% , RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC

3 RETIC parameters: RETIC, RETIC_ABS, IRF

Mode Whole blood, Prediluted
Sample volume Whole blood 20 µl, Prediluted 20 µl
Dimension of aperture WBC: 100 µm, RBC/PLT: 68 µm
General throughput Up to 60 samples/hour with 50 autoloader positions
Storage Up to 200.000 sample results including histograms
QC mode LJ, X, XR, XB etc.
Calibration mode 3 calibration modes: automatic calibration, whole blood calibration and manual calibration
Windows operating system
Display PC display (14 inch color TFT)
Power supply 220V~50/60 Hz
Interface Bidirectional LIS and barcode reading
Report External printer
Automatic reagent residual alarm, different warning alarms announce probable abnormalities of the specimen
Dimensions 660x560x545mm (WxDxH), 73 kg

 

 

Reviews

There are no reviews yet.

Be the first to review “Phoenix NCC-51 Hematology Analyzer”

Your email address will not be published. Required fields are marked *

Hazina Place, 2nd Floor, Off Ngong Road

Call us now on

Call us now on

+254 742 32 45 53 | +254 779 865 372

Email us at

Email us at

info@ketonconsulting.com

Quotations

Quotations

Get a Quote Now